ULTRASTAR

INNOVATIVE RUBBER CONSTRUCTION, SUPERIOR BARRIER TYPE IMPERMEABILITY

TECHNICAL DATA
# # # # # # # # #
PART REF. HOSE SIZE R.O.D O.D MAX. W.P BURST MIN. BEND WEIGHT FITTINGS
DN dash inch mm inch mm inch bar psi bar psi mm inch g/m lb/ft Std 1 Std 2
H01133005* 5 -4 3/16" 11,2 0,44 13,0 0,51 35 500 150 2170 85 3,35 217 0,15 SC+C00300-04 SF+K00400-04
H01133008* 8 -6 5/16" 15,4 0,61 17,2 0,68 35 500 150 2170 85 3,35 336 0,23 SC+C00300-06 SF+K00400-06
H01133010* 10 -8 13/32" 17,5 0,69 19,3 0,76 35 500 150 2170 95 3,74 385 0,26 SC+C00300-08 SF+K00400-08
H01133012* 12 -10 1/2" 21,6 0,85 23,4 0,92 35 500 150 2170 115 4,53 533 0,36 SC+C00300-10 SF+K00400-10
H01133016* 16 -12 5/8" 25,5 1,00 27,3 1,07 35 500 150 2170 135 5,31 676 0,45 SC+C00300-12 SF+K00400-12
H01133022* 22 -16 7/8" 29,5 1,16 31,5 1,24 35 500 150 2170 100 3,94 724 0,49 SC+C00300-16 SF+K00400-16
H01133028* 28 -20 1.1/8" 36,1 1,42 38,1 1,50 35 500 150 2170 120 4,72 900 0,60 SC+C00300-20 SF+K00400-20
H01133035* 35 -24 1.3/8" 42,8 1,69 44,8 1,76 35 500 150 2170 120 4,72 1214 0,82 SF+K00400-24

KEY FEATURES

• Very low permeability to refrigerant fluids (performance with R134a < 5 kg/m2/yr), equivalent to type E hoses • High flexibility

APPLICATIONS & FLUIDS

• Bus and off-highway equipment air-conditioning systems
• Recommended lubricants: PAG, POE
• Not recommended with refrigerant gases using mineral oils as lubricants
• Refrigerants: R134a; R1234yf

CONTINUOUS SERVICE TEMPERATURE RANGE

-40 °C, -40 °F
125 °C, 257 °F

TUBE

Unique molecular barrier compound made from synthetic rubber (CIIR) and advanced materials

REINFORCEMENT

One steel wire braid

COVER

High temperature and environment resistant synthetic rubber

APPLICABLE SPECS

SAE J3062 Type B Class I (meets the performance of Type E); SAE J2064

TYPE APPROVALS

CU-TR

REMARKS

• Guaranteed performance only with Manuli fittings
• Ask Manuli Hydraulics about other refrigerants and lubricants