TECHNICAL DATA

SIZE

WORKING
PRESSURE
Dynamic

RATED FLOW
at 0.2 MPa of
pressure drop

CONNECTION
EFFORT

OIL SPILLAGE
Connection /
Disconnection

MINIMUM BURST PRESSURE

CONNECTION /
DISCONNECTION
UNDER
PRESSURE

DN

inch

Dash

MPa

PSI

l/min

US
GPM

N

lb.

cc.

cubic
inch

Male

Female

M & F

MPa

PSI

MPa

PSI

MPa

PSI

6 1/4 4 35 5,075 5 1.3 60 13.5 0.7 0.043 200 29,000 150 21,750 150 21,750 Not allowed
10 3/8 6 35 5,075 37 9.2 80 18.0 1.4 0.085 140 20,300 150 21,750 150 21,750 Not allowed
12 1/2 8 30 4,350 68 19.8 80 18.0 2.0 0.122 125 18,125 150 21,750 150 21,750 Not allowed
19 3/4 12 25 3,625 142 38.8 90 20.2 7.0 0.427 100 14,500 120 17,400 100 14,500 Not allowed
25 1 16 25 3,625 250 66.1 90 20.2 11.0 0.671 100 14,500 100 14,500 100 14,500 Not allowed
32 1.1/4 20 25 3,625 390 103.0 90 20.2 15.0 0.915 100 14,500 100 14,500 105 15,225 Not allowed
38 1.1/2 24 22 3,190 553 146.1 100 22.5 21.0 1.281 90 13,050 100 14,500 100 14,500 Not allowed
51 2 32 15 2,175 838 221.4 225 50.6 45.0 2.746 60 8,700 60 8,700 90 13,050 Not allowed
The rated flow represents the normal operating condition. The maximum recommended flow rate is equal to 1.5 times the rated flow

PRODUCT DESCRIPTION

• Reference series on the agriculture and industrial market
• Simple connection and disconnection by pulling back the sleeve
• Positive, quick connection of the male into the female by the latching ball system
• Shut-off by poppet valve
• High resistant materials and hardened male and sleeve to withstand the brinelling effect
• Interchangeability according to ISO 7241 series A

MATERIAL

Female and male couplings in steel, with some hardened areas, in correspondence to the most stressed points. Springs in C98 steel, seals in NBR (other materials on request) and back-up ring in PTFE. PU seal on ½” female available on request.

WORKING TEMPERATURE

-22ºF up to +230ºF (-30ºC up to +110ºC)
For other temperatures, the coupling may be assembled with the specific seals

SAFETY FACTOR

4:1 for dynamic pressures

IMPULSE PRESSURES

100,000 cycles at 133% of the rated one (freq. 1Hz)

TEST SPECIFICATIONS

ISO 18869